Cat.No. | Volume(L) | Cap Style | Size(mm) | /Case |
Height | Bottleneck Diameter | Bottom Diameter |
785101 | 2.0 | Seal Cap | 213.5 | 67 | 162 | 4 |
785111 | 2.0 | Vent Filter Cap | 213.5 | 67 | 162 | 4 |
786101 | 3.0 | Seal Cap | 253.5 | 67 | 162 | 4 |
786111 | 3.0 | Vent Filter Cap | 253.5 | 67 | 162 | 4 |
787001 | 5.0 | Seal Cap | 285.5 | 90 | 230 | 4 |
787011 | 5.0 | Vent Filter Cap | 285.5 | 90 | 230 | 4 |
786501(new) | 3L Wide Mouth | Seal Cap | 253.5 | 90 | 162 | 4 |
786511(new) | 3L Wide Mouth | Vent Filter Cap | 253.5 | 90 | 162 | 4 |

PC Bottle & HDPE Cap & Nylon Handle, Vent caps with 0.2um hydrophobic filters for gas exchange without contamination.

Ideal for shaker culture applications.

• PC bottle, which meets the USP Class 6 Standard, with high transparency, has strong impact resistance, oxidation resistance and canwithstand a high temperature up to 121℃.
• There’s a scale made by injection molding on the flask body to facilitate observing the filled liquid volume.
• Sterilized by E-beam, SAL=10-6
• Non-Pyrogenic, DNase/Rnase free
• Individually packaged in sterile bag
New added 3-L wild-mouth high-efficiency Erlenmeyer flask
The bottom diameter of the 3-L wild-mouth high-efficiency Erlenmeyer flask is consistent with that of the 3-L high-efficiency Erlenmeyer flask, and its mouth diameter adopts the neck size of the 5-L high-efficiency Erlenmeyer flask, which not only saves space usage, but also increase oxygen flux, so as to increase the efficiency of cell culture.

Tips:
· Recommended volume :30-40% of the bottle volume;
· Rotation speed suggestion: the starting speed is 75-125RPM, you can control the rotation speed according to the situation;
· The liquid shake shaker should pay attention to the water level, the gas shake shaker should pay attention to the temperature;
Transfer Cap for High Efficiency Erlenmeyer Flask
Bi-directional Liquid Transfer Cap
Bi-directional liquid transfer cap is used along with a 2L, 3L or 5L shake flask to connect a liquid inlettubing with the required device. The liquid transfer is achieved by connection of a peristaltic pump between the erlenmeyer flask and the device. Upon completion of the transfer, the transfer cap can be replaced with a vent cap for culture. |  |
Multifunctional Liquid Transfer Cap
Unlike the bi-directional liquid transfer cap, the multifunctional transfer cap can be directly placed in an incubator for culture after the liquid transfer is completed. It can reach a large air flux. The sampling part is composed of a sampling nozzle and a one-way valve, which can prevent the liquid from flowing backwards during the sampling process and ensure the aseptic sampling. The liquid inlet tubing is provided with a PTFE needle filter, which solves the issue of liquid remaining in the tubing during the feeding process. |  |
Inverted Liquid Transfer Cap
The inverted transfer cap is used along with a 2L, 3L or 5L erlenmeyer flask to connect a liquid inlet tubing with the required device. When liquid transfer is required, the liquid is transferred under gravity with the inverted erlenmeyer flask. |  .jpg)
|
5L Efficient Erlenmeyer Flask (with tube)
.jpg)

• It is pre-installed on the High Efficiency Erlenmeyer Flask, which realizes the closed transfer of liquid and reduces the risk of external
contamination during the process of capping and screwing
• The Transfer Cap comes with a large filter membrane, high oxygen flux, and no external air filter is required to ensure high-density culture of cells, while the overall height is reduced, the applicable range of the shaker is wider, and the utilization rate of the shaker is increased.
Cat.No. | Product Name | Tube Information | Tube Length | /Case |
787081 | 5L Efficient Erlenmeyer Flask (with tube) | TPE Thermoplastic Hose, Hose Diameter: 1/8" ID, 1/4" OD | 30 cm + 30 cm | 4
|

It is applicable to liquid transfer and culture during mass proliferation of bacteria and suspension cells.

• Closed system reduces the risks of contamination during liquid transfer.
• The caps and connection points are a one-piece construction, reducing the risks of leakage and media residue.
• A variety of tubing diameters are available and aseptic welding of liquid inlet tubing under normal conditions is supported.
• High-quality materials and smooth inner wall of the tubing provide an excellent transfer performance.
• Sterilized by E-beam, SAL=10-6
.• Endotoxin-free, and no ingredients of animal origin.
• Individually packaged in sterile bag.
Cat.No. | Name | Information | Pipe length | Pipe connect | /pack | /case |
785931 | Multifunctional Liquid Transfer Cap for 2L | Thermoplastics Pipes Pipe Diameter: 1/8" ID, 1/4" OD, Pipe Connect: Aseptic welding / Heat-seal | 50cm | Aseptic welding heat-seal | 1 | 4 |
786931 | Multifunctional Liquid Transfer Cap for 3L | 50cm | Aseptic welding heat-seal | 1 | 4 |
787931 | Multifunctional Liquid Transfer Cap for 5L, and 3L Wide-mouth | 92cm | Aseptic welding heat-seal | 1 | 4 |
785921 | Bi-directional Liquid Transfer Cap for 2L | 50cm | Aseptic welding heat-seal | 1 | 4 |
786921 | Bi-directional Liquid Transfer Cap for 3L | 50cm | Aseptic welding heat-seal | 1 | 4 |
787921 | Bi-directional Liquid Transfer Cap for 5L, and 3L Wide-mouth | 92cm | Aseptic welding heat-seal | 1 | 4 |
785941 | Inverted Liquid Transfer Cap for 2L | 50cm | Aseptic welding heat-seal | 1 | 4 |
786941 | Inverted Liquid Transfer Cap for 3L | 50cm | Aseptic welding heat-seal | 1 | 4 |
787941 | Inverted Liquid Transfer Cap for 5L, and 3L Wide-mouth | 92cm | Aseptic welding heat-seal | 1 | 4 |
785951 | Inverted Liquid Transfer Cap for 2L, Thick Outlet Pipe | Thermoplastics Pipes Pipe Diameter: 1/4" ID, 7/16"OD, Pipe Connect: Aseptic welding / Heat-seal | 50cm | Aseptic welding heat-seal | 1 | 4 |
786951 | Inverted Liquid Transfer Cap for 3L, Thick Outlet Pipe | 50cm | Aseptic welding heat-seal | 1 | 4 |
787951 | Inverted Liquid Transfer Cap for 5L, and 3L Wide-mouth, Thick Outlet Pipe | 92cm | Aseptic welding heat-seal | 1 | 4 |